Showing results: 1081 - 1095 of 2704 items found.
-
Advanced Probing Systems, Inc.
APS produces electro-chemically machined pins in diameters between .020"-.040" in a variety of materials for use in various applications. These “large diameter pins” are used in various medical applications, industrial applications, board testing, LED & LCD test and as components in small tools. APS’s design services can help you select the optimal material from tungsten, beryllium-copper, Paliney 7® or various stainless steel alloys or work with the material of your choice. Pins can be produced with either a sharp or radius (rounded) tip. Tapers can be highly polished, slightly polished, matte or neutral in finish.
-
BPS Series -
AMETEK Programmable Power, Inc.
The BPS Series consists of multiple high power AC power systems that provide controlled AC output for ATE and product test applications. This high power AC test system covers a wide spectrum of AC power applications at an affordable cost. Using state-of-the-art PWM switching techniques, the BPS Series combines compactness, robustness and functionality in a compact floor-standing chassis, no larger than a typical office copying machine. This higher power density has been accomplished without the need to resort to elaborate cooling schemes or additional installation wiring. Simply roll the unit to its designated location (using included casters), plug it in, and the BPS Series is ready to work for you.
-
LXinstruments GmbH
Among other things, solar array simulators are required for testing satellite power supplies. An SAS (Solar Array Simulator), consisting of an interconnection of several Solar Array Simulator modules, maps the solar panels and displays the individual strings connected in parallel. Optionally, the individual SAS modules are monitored by a Second Level Protection, so that the test object is not damaged in case of errors with the voltage sources. Additional circuitry is implemented via project-specific test modules. The signal path to the DUT can be separated, e.g. for dynamic current measurements.The Keysight Solar Array Simulators used were specially developed for satellite applications and cover the significantly higher requirements regarding the control speed of MPP tracking compared to terrestrial applications.
-
AXC1553-x -
AIM GmbH
MIL-STD-1553 Test and Simulation modules for XMC with 1, 2 or 4 dual redundant streams plus 8 Discrete I/O’s (on Rear-I/O).*Concurrent BC, MRT (31) & Chronological/Mailbox Bus Monitor*Full Error Injection/Detection (AS4112)*Complex Triggering, Data Capture/Filtering and 100% Bus Recording*Physical Bus Replay*IRIG-B Time Encoder/Decoder*Full Function, Single Function and Simulator Only versions available*Drivers for Linux and Windows*Drivers for other embedded applications are available on request*Optional Databus Test and Analysis Software and RT Production Test Plan
-
EIIT, S.A.
New polymers are constantly being developed and component manufacturing techniques appear, allowing the gradual replacement of metallic materials by plastics or composites, in various fields of application, in different industries. In particular, in the air conditioning, heating and water supply sector, plastic components are subject to the aging process due to the temperature to which they are subjected or due to the amount of oxygen in the fluids. The Test System for Longevity and Accelerated Aging Tests developed by Controlar allows to foresee, in accelerated test, the wear throughout the life of the plastic components of the hydraulic systems, in order to prevent eventual failures during the useful life cycle of the DUT.
-
Chroma 11022/11025 -
Chroma Systems Solutions, Inc.
The Chroma 11022 and 11025 LCR Meters are passive component testers that can give you the most cost effective alternative equivalent to the high priced meters. They are designed for the demanding applications in production test, incoming inspection, component design and evaluation. Programmable test signal level settings are from10mV to 1V in a step of 10mV, and the VM/IM signal level monitor functions allow you to evaluate your devices at the level you specify. Ten test frequencies of 50Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, and 100kHz, can be used to evaluate passive components and transformers/ LF coils.
-
E9304A -
Keysight Technologies
Refer to the E9301A for standard power sensor features Low frequency coverage (9 kHz to 6 GHz) for EMC/EMI test applications such as the radiated immunity test (IEC61000-4-3)High sensitivity (-60 to +20 dBm) and fast measurement speed to reduce the time taken to calibrate radiated field uniformity and EMC/EMI test receivers Measure transmitter power and receiver sensitivity at Very Low Frequency (VLF) to microwave frequencies Special option available to 18 GHz Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
RDS -
MOTOMEA
The principle of the test is to use a dynamic adjustable load with a servomotor that functions as a LOAD to the motor under test. The servo drive is fed through KEB R6 (regenerative unit).In our test bench, the loading motor operates as a generator. Historically, the regenerative energy was wasted into heat using resistors batteries. The MEA Regenerative Dynamometer System solution is to return the energy back into the main line power supply, eliminating heat and ultimately providing a real return on investment for the owner/operator of the system.This is particularly useful in all applications where prolonged or continuous downward motion occurs, or heat dissipation to the surrounding environment is not wanted.
-
N4952A -
Keysight Technologies
The N4952A is an affordable and compact error detector remote head available in 4 to 17 Gb/s and 5 to 32 Gb/s configurations. Compatible with the N4960A Serial BERT controller, it is the perfect solution to test up to 32 Gb/s per channel for 100 Gigabit Ethernet applications and other high-data rate devices. The N4952A error detector supports PRBS or user patterns and operates up to 32 Gb/s in a single band with no gaps or missing data rates. The remote head allows the test equipment to be located very close to the device under test, eliminating the need for long cables that degrade signal quality.
-
Hangzhou Xun Anda Electrical Co., Ltd.
1. Test application: 12V batteries test and 12V Starting/Charging system test.2. Test battery type: regular liquid, AGM battery, GEL battery.3. CCA test range: 200~1200CCA (SAE).4. Voltage test range: 7V~15V.5. Test for multiple battery standards: SAE, DIN, EN, IEC, CA.6. LED display to show test result: 4 digital + 3 LED lamp
-
ST-3347W -
Standard Instruments Co., LTD.
This clamp meter provides accurate AC, AC/DC current and voltage readings regardless of the waveforms. This meter can use in most industrial and commercial applications where non-linear loads distort the current or voltage waveform. Reliable operation. Features accessories such as test leads, carrying case and temperature probe.
-
Premier Electrosystems
Premier's Temperature Controller also known as PID Controllers are tried and tested for several applications. Some of those are are food processing, storage, plastic extrusion, thermo forming machines, ovens, furnaces, ceramic kilns, boilers, heat exchangers, auto claves, incubators and laboratory test chambers.
-
410104538 -
Virginia Panel Corporation
The 50 module ITA can be used in a number of applications to accomplish the required connection to the Unit Under Test (UUT). You can mount a VPC front or rear mount enclosure or customize your own fixture to be attached on the frame. A wide range of ITA modules are available separately for user configuration.
-
MegiQ BV
Our test equipment is more than a test-set with a screen. Our application software provides an integrated tool to easily store the measurements at different stages and create a log of what we have done. Each measurement stores all data and settings, including display, markers and calibration.
-
Serie DY-2 -
PASI srl
The DY-2 FAMILY of automated pull-off testers covers the complete range of pull-off applications with unmatched ease of operation and a unique capability to store a complete record of the test.Pull-off testing is one of the most widely used test methods in the construction industry. This is reflected in the huge number of standards dedicated to the method.